GMP Standard Synthesis Hot Cell for Radiopharmaceutical Production with Lead Equivalent Shielding and Stainless Steel Structure
| Herkunftsort | CHINA |
|---|---|
| Markenname | Jovi |
| Modellnummer | JVVMED-HC |
| Dokumentieren | JVVMEG-HCFH50-PET.pdf |
| Min Bestellmenge | 1 Set |
| Preis | $35000~$95623 |
| Verpackung Informationen | in Holzgehäuse |
| Lieferzeit | 25 Arbeitstage nach Erhalt Ihrer Zahlung |
| Zahlungsbedingungen | T/t im Voraus |
| Versorgungsmaterial-Fähigkeit | 100SETS/YEAR |
Treten Sie mit mir für freie Proben und Kupons in Verbindung.
whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
Wenn Sie irgendein Interesse haben, leisten wir 24-stündige Online-Hilfe.
xProduktdetails
| Sauberkeit | Klasse ABC | Bleiäquivalent | 10 mmpb 20 mmpb 50 mmpb 100 mmpb |
|---|---|---|---|
| Material | Edelstahlkonstruktion, Bleiziegel | Betriebssystem | Künstliche Intelligenzkontrolle |
| Reinigungsmethode | Aktiver Kohlenstofffilter, HEPA -Filtration, | Desinfektionsmethode | Ultraviolettes Licht und Ozon |
| Alternative Optionen | Manueller Spender, automatischer Spender | Produktname | Synthese heiße Zelle für die radiopharmazeutische Produktionslinie GMP -Standard |
| Hervorheben | Lead Equivalent Shielding Synthesis Hot Cell,Stainless Steel Structure Radiopharmaceutical Production Hot Cell,Lead Bricks Shielding Hot Cell |
||
Produkt-Beschreibung
GMP Standard Synthesis Hot Cell for Radiopharmaceutical Production
The synthesis hot cell (also known as a synthesis shielding box or hot cell) is the core equipment in the radiopharmaceutical production process. Its design ensures the safety of operators, the environment, and the product itself, featuring Class A/B/C cleanliness standards with real-time dose monitoring, HEPA filtration, and active carbon filtration in a negative pressure environment.
Key Characteristics
Radiation Shielding
The most critical feature, effectively shielding high-energy gamma rays or neutrons emitted by radionuclides.
- Materials: High-density lead (Pb) bricks or plates as primary shielding material, with lead glass for viewing windows and steel for structural support
- Thickness: Precisely calculated based on radionuclide type and activity, ranging from a few centimeters to several tens of centimeters to ensure radiation dose rates remain below safe regulatory limits (typically below 2.5 μSv/h)
Containment, Negative Pressure & HEPA Filtration
- Containment: Highly sealed system to prevent leakage of radioactive aerosols or volatile substances
- Negative Pressure System: Maintains internal air pressure lower than surrounding room to prevent contaminant escape
- HEPA Filtration: Multiple-stage High-Efficiency Particulate Air filters capture radioactive particles, with activated carbon filters for volatile radionuclides
Remote Manipulation & Automation
Enables operation without direct hand contact with internal items:
- Manipulators: Master-slave manipulators or electric-powered manipulators controlled by joysticks/touchscreens
- Full Automation Systems: Computer-program-controlled automated modules perform entire synthesis processes, reducing human intervention and improving repeatability
Product Protection & Aseptic Environment
Meets stringent standards for sterile, pyrogen-free radiopharmaceuticals:
- Internal Environment: Clean environment meeting Grade C or A (ISO Class 7 or 5) standards
- Transfer Systems: Dedicated pass-through boxes with interlocking mechanisms and UV lights
- Surface Materials: Smooth, seamless stainless steel surfaces resistant to frequent disinfection
Shielding Viewing Window
Special lead glass windows provide necessary transparency while offering equivalent radiation shielding to lead walls, typically multi-layered and very thick.
Utilities Integration
Comprehensive utility interfaces for production:
- Electrical: Powers instruments, manipulators, lighting
- Pneumatic: Supplies compressed air or inert gases
- Vacuum: Used for filtration or liquid transfer
- Cooling/Ventilation: Independent systems to maintain stable temperature
Monitoring & Safety Systems
- Radiation detectors continuously monitor internal levels
- Pressure monitoring displays negative pressure status with alarm triggers
- Temperature and smoke sensors prevent safety incidents
- Safety interlocks on doors and pass-through boxes prevent radiation leakage
A radiopharmaceutical synthesis hot cell is a complex engineering system integrating radiation shielding, containment, remote/automated operation, and sterile control. Modern designs emphasize high integration, automation, and modularization to reduce operational complexity and radiation exposure risks while maintaining strict GMP quality standards.